Testing Charges

EMC Full Compliance Testing Charges

  Sr. No Test Name Standard Charges (INR)*
1. Radiated Emission Test (150 kHz to 1 GHz) IEC 60601-1-2, CISPR 11 12000#
2. Radiated Emission Test (150 kHz to 18 GHz) IEC 60601-1-2, CISPR 11 18000#
3. Radiated Susceptibility Test up to 6 GHz IEC 60601-1-2, IEC 61000-4-3 30000#
4. Conducted Emission Test (9 kHz to 30 MHz) (power line, single phase) IEC 60601-1-2, CISPR 11 10000
5. Conducted Emission Test (9 kHz to 30 MHz) - each signal/data line 5000
6. Conducted RF Susceptibility Test (150 kHz to 80 MHz) (power line, single phase) IEC 60601-1-2, IEC 61000-4-6 15000
7. Conducted Susceptibility Test (150 kHz to 80 MHz,- each signal/data line 6000
8. Electrostatic Discharge Test – Air and Contact IEC 60601-1-2, IEC 61000-4-2 10000
9. Electric Fast Transient (EFT) Test, (power line, single phase) IEC 60601-1-2, IEC 61000-4-4 8000
10. Electric Fast Transient (EFT) Test (each data/signal line) 4000
11. Surge Immunity Test (power line, single phase) IEC 60601-1-2, IEC 61000-4-5 10000
12. Surge Immunity Test (each data/signal line,) 6000
13. Power Frequency Magnetic Field (Max. 100 Ampere) IEC 60601-1-2, IEC 61000-4-8 7000
14. Voltage Dips & Interruptions IEC 60601-1-2, IEC 61000-4-11 8000
15. Harmonics Test IEC 60601-1-2, IEC 61000-3-2 8000
16. Flicker Test IEC 60601-1-2, IEC 61000-3-3 10000

* The GST will be charged 18% on the above-mentioned price.

# Testing charges are applicable for one day only.

Note: Please request a quote for EMC testing using other IEC / CISPR standards.

EMC Pre-Compliance Testing Charges

  Sr. No Test Name Standard Charges (INR)*
1 Radiated Emission Test (150 kHz to 1 GHz) IEC 60601-1-2, CISPR 11 10000#
2 Radiated Emission Test (150 kHz to 18 GHz) IEC 60601-1-2, CISPR 11 15000#
3 Radiated Susceptibility Test up to 6 GHz IEC 60601-1-2, IEC 61000-4-3 25000#
4 Conducted Emission Test (9 kHz to 30 MHz) (power line, single phase) IEC 60601-1-2, CISPR 11 8000
5 Conducted Emission Test (9 kHz to 30 MHz) - each signal/data line 4000
6 Conducted RF Susceptibility Test (150 kHz to 80 MHz) (power line, single phase) IEC 60601-1-2, IEC 61000-4-6 12000
7 Conducted Susceptibility Test (150 kHz to 80 MHz,- each signal/data line 5000
8 Electrostatic Discharge Test – Air and Contact IEC 60601-1-2, IEC 61000-4-2 7000
9 Electric Fast Transient (EFT) Test, (power line, single phase) IEC 60601-1-2, IEC 61000-4-4 6000
10 Electric Fast Transient (EFT) Test (each data/signal line) 4000
11 Surge Immunity Test (power line, single phase) IEC 60601-1-2, IEC 61000-4-5 8000
12 Surge Immunity Test (each data/signal line,) 5000
13 Power Frequency Magnetic Field (Max. 100 Ampere) IEC 60601-1-2, IEC 61000-4-8 7000
14 Voltage Dips & Interruptions IEC 60601-1-2, IEC 61000-4-11 7000
15 Harmonics Test IEC 60601-1-2, IEC 61000-3-2 6000
16 Flicker Test IEC 60601-1-2, IEC 61000-3-3 8000

* The GST will be charged 18% on the above-mentioned price.

# Testing charges are applicable for one day only.

Note: Please request a quote for EMC testing using other IEC / CISPR standards.

Safety Full Compliance Testing Charges

  Sr. No Test Name Standard Charges (INR)*
1. Dielectric Strength (AC/DC) Test IEC 60601-1 4000
2. Leakage Current Test (Earth, Touch, Patient Leakage, Patient Auxiliary) IEC 60601-1 8000
3. Ground Bond Test IEC 60601-1 3500
4. Insulation Resistance Test IEC 61010-1 3500
5. Humidity preconditioning treatment (24 hrs) (1 Slot) IEC 60601-1 5000
6. Humidity preconditioning treatment (48 hrs) ( 2 slot) IEC 60601-1 9000
7. Heating Treatment (1 slot) IEC 60601-1 3500
8. Impact Test IEC 60601-1 2000
9. Mechanical Hazard associated with surfaces, corners, and edges IEC 60601-1 2000
10. Ball Pressure Test IEC 60601-1 2500
11. Legibility and durability of markings test IEC 60601-1 2000
12. Sound Pressure level Test IEC 60601-1 2000
13. UV Radiation test IEC 60601-1 2000
14. Clearance and creepage distance test IEC 60601-1 3000
15. Cord guard test IEC 60601-1 2000
16. Instability Hazard Test IEC 60601-1 2500

* The GST will be charged 18% on the above-mentioned price.

Safety Pre-Compliance Testing Charges

  Sr. No Test Name Charges (INR)*
1 Dielectric Strength (AC/DC) Test 3000
2 Leakage Current Test (Earth, Touch, Patient Leakage, Patient Auxiliary) 6000
3 Ground Bond Test 3000
4 Insulation Resistance Test 3000
5 Humidity preconditioning treatment (24 hrs) (1 Slot) 4500
6 Humidity preconditioning treatment (48 hrs) ( 2 slot) 8500
7 Heating Treatment (24 hrs) (1 slot) 3000
8 Impact Test 1500
9 Drop Test 1500
10 Mechanical Hazard associated with surfaces, corners, and edges 1500
11 Ball Pressure Test 2000
12 Legibility and durability of markings test 1000
13 Sound Pressure level Test 1500
14 UV Radiation test 1500
15 Clearance and creepage distance test 2000
16 Cord anchorage and cord guard test 1500
17 Instability Hazard Test 2000
18 Flammability Test 2000

* The GST will be charged 18% on the above-mentioned price.